Dimensions
|
CAPACITY
|
A
|
B
|
C
|
D
|
E
|
CABLE LENGTH
|
|
500-2.5K
|
3.782
|
2.590
|
2.650
|
6.500
|
7.500
|
15’
|
|
4K
|
3.946
|
2.590
|
2.650
|
6.500
|
7.500
|
15’
|
|
5K
|
4.030
|
2.838
|
2.650
|
6.500
|
7.500
|
15’
|
|
10K
|
4.280
|
3.088
|
3.900
|
7.500
|
7.500
|
15’
|
Description &
Stock #
|
Part
Number |
Capacity |
Weight |
Price |
Buy |
| RTM-500 |
500
lb |
17
lb |
554.45 |
Use drop down arrow

to select part number
|
| RTM-1.25K |
1,250
lb |
17
lb |
554.45 |
| RTM-2.5K |
2,500
lb |
17
lb |
554.45 |
| RTM-4K |
4,000
lb |
17
lb |
554.45 |
| RTM-5K |
5,000
lb |
18
lb |
596.70 |
| RTM-10K |
10,000
lb |
21
lb |
696.15 |
|
Replacement
Load Cells |
| RTM-500-beam |
500
lb |
2
lb |
284.05 |
| RTM-1.25K-beam |
1,250
lb |
2
lb |
284.05 |
| RTM-2.5K-beam |
2,500
lb |
2
lb |
284.05 |
| RTM-4K-beam |
4,000
lb |
2
lb |
284.05 |
| RTM-5K-beam |
5,000
lb |
2
lb |
393.25 |
| RTM-10K-beam |
10,000
lb |
2
lb |
463.45 |
|
Specifications
| Rated capacities |
Klbs
|
0.5 |
1.25 |
2.5 |
4 |
5 |
10 |
| Rated output |
mV/V
|
2.0 +/- 0.2
|
| Combined error |
%
|
0.03
|
| Nonrepeatability |
%
|
0.01
|
| Creep in 20
minutes |
%
|
0.03
|
| Zero balance |
%
|
1.0
|
| Compensated temp.
range |
F/ C
|
+15
…+104
/-10
…+40
|
| Temperature
effects on rated output |
% of load
/ 100
F/40 C
|
0.08
|
| Temperature
effects on zero balance |
% / 100
F/40 C
|
0.25
|
| Terminal
resistance – input |
min. Ohm
|
350
|
| Terminal
resistance – output |
nom. Ohm
|
350
|
| Excitation
voltage |
Max Vdc or Vac
rms
|
15
|
| Insulation
resistance |
min. Mohm
|
5000
|
| Max. safe load |
%
|
150
|
| Ultimate overload |
%
|
300
|
| Max. safe side
load |
%
|
100
|
| Deflection at
rated load |
%
|
0.010
|
0.010
|
0.010
|
0.010
|
0.010
|
0.012
|
| Weight |
Lbs
|
16.4
|
16.4
|
16.4
|
16.4
|
18
|
20.5
|
|
All stainless steel construction, this tank mount assembly uses a
hermetically sealed beam load cell with a blind load hole that has a flat
loading surface. Expansion and contraction due to thermal changes and side
load from external forces are handled with rocker pin mounting. After the
side load has been removed the mount will re-center itself using the rocker
pin. This mount is unequalled for repeatability.
|