Revere
Transducer model 5223 Double-ended truck scale link beam
|
Model
5223
Double-Ended Link Beam |
 |
| Features |
Description |
- Capacity range of 50,000 to
200,000 pounds
- Nickel plated alloy steel
- Hermetically sealed
- Conduit adapter standard
- Operational temperature range
from -65 F to 200 F
- Factory Mutual approved for
intrinsic safety
- Exceeds NEMA6 and IP67
standards for wash down resistance
- 3 year warranty
- Certified to OIML R60, Class C,
3000d
- NTEP Class IIIL, 10,000d
- Weighing assemblies available
|
|
Beam
only |
| Part
Number |
Capacity |
Weight |
Price |
Buy |
| 5223-B10-50K-40P1 |
50,000
lb |
16
lb |
613.20 |
Use drop down arrow

to select part number
|
| 5223-B10-65K-40P1 |
65,000
lb |
16
lb |
613.20 |
| 5223-B10-100K-40P1 |
100,000
lb |
16
lb |
865.20 |
| 5223-B10-125K-40P1 |
125,000
lb |
16
lb |
865.20 |
| 5223-B10-200K-40P1 |
200,000
lb |
32
lb |
987.00 |
|
EZ
Mount II |
| EZ Mount II for
5223 |
50K
- 65K |
148
lb |
405.00 |
| EZ Mount II for
5223 |
100,000
lb |
148
lb |
564.00 |
| EZ Mount II for
5223 |
200,000
lb |
715
lb |
1,740.00 |
|
| Applications |
EZ Mount II |
-
Truck scales
-
Rail Road
Scales
-
Process
weighing
|

|
|
Dimensions |
 |
| Capacity |
A |
B |
Cr |
D |
F |
J |
K |
L |
N |
P |
Sr |
T |
| 50K, 65K,
100K, 125K |
8.50 |
4.25 |
1.00 |
3.00 |
3.00 |
2.20 |
1.03 |
10.25 |
2.40 |
2.06 |
1.00 |
0.28 |
| 200K |
10.00 |
5.00 |
1.50 |
3.40 |
3.40 |
2.50 |
1.03 |
12.00 |
2.75 |
2.35 |
1.50 |
0.40 |
|
|
|
|
Specifications |
| Model |
5223 |
| Capacities
(lbs) |
50K, 65K, 100K, 125K, 200K |
| Accuracy
Class: |
IIIL |
| Maximum
Divisions: |
10,000 |
| Minimum
Division: |
0.0043 |
| Excitation
(VDC or VAC): |
10 Nom. 15 Max. |
| Rated
Output (mV/V): |
3 +/- 0.003 |
| Zero
Balance (% FS): |
1.0 |
Resistance:
Input (ohms):
Output (ohms): |
700 +/- 7
700 +/- 7 |
| Combined
Error (%FS)²: |
0.02 |
| Non-Repeatability
(%FS): |
0.01 |
| Creep (%
Ld / time, -10 C to 40 C): |
0.05 / 1 hr. |
| Temp.
Effect: Output (% Ld /10 F /% Ld /5 C): |
0.008 (0.0072) |
| Zero (% FS
/ 10 F /% FS / 5 C) |
0.010 (0.009) |
| Temp.
Range: Compensated ( F/ C) |
14 F to 104 F (-10 C to
40 C) |
| Operating
( F / C) |
-65 F to 200 F (-50 to
90 C) |
| Safe
Overload (%FS): |
150 |
| Ultimate
Overload (%FS): |
300 |
| Safe
Sideload (% FS): |
100 |
|
|
|
|